Medical equipment

medical
Richell Logo R

Excellent properties of MicroResico®

low adsorption

We have achieved low adsorption of proteins and peptides without the need for surface hydrophilic treatment with our proprietary MicroResico®.

Peptide adsorption test

Peptide adsorption test

Peptide adsorption test method

1) Incubate the BSA tryptic digest for 24 hours
2) After concentrating to dryness, dissolve in 0.1% TFA/H2O and use as the sample solution.
3) Analyze sample solution by Nano-RP-HPLC

Protein adsorption test

Protein adsorption test

Protein adsorption test method

1) Adiponectin (0.75ng/ml) incubation for 3 hours
2) Quantification of Adiponectin in aqueous solution by ELISA method

sharp liquid cut

In biochemical experiments, where very small amounts of samples are often handled, sample loss due to poor sample collection efficiency affects experimental accuracy.
MicroResico® sample tubes minimize sample loss.

Liquid depletion test

Liquid depletion test

Drainage test method

1) Incubate dye (Bordeaux S) aqueous solution for 1 hour
2) After removing the dye solution by pipetting, add water and measure the absorbance.